5. PARAMETERS
5 - 45
5.2.7 Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ])
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PL01
LIT1
Linear servo motor/DD motor function selection 1
Select a magnetic pole detection timing of the linear servo motor/DD motor and stop interval of
the home position returning.
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x Linear servo motor/DD motor magnetic pole detection selection
The setting value "0" will be enabled only with absolute position
linear encoders.
0: Magnetic pole detection disabled
1: Magnetic pole detection at first servo-on
5: Magnetic pole detection at every servo-on
1h
_ _ x _ For manufacturer setting 0h
_ x _ _ Stop interval selection at the home position return
Set a stop interval of the home position returning.
The digit is enabled only for linear servo motors.
0: 2
13
(= 8192) pulses
1: 2
17
(= 131072) pulses
2: 2
18
(= 262144) pulses
3: 2
20
(= 1048576) pulses
4: 2
22
(= 4194304) pulses
5: 2
24
(= 16777216) pulses
6: 2
26
(= 67108864) pulses
3h
x _ _ _ For manufacturer setting 0h
PL02
LIM
Linear encoder resolution - Numerator
Set a linear encoder resolution per
v
m in [Pr. PL02] and [Pr. PL03].
Set the numerator in [Pr. PL02].
This is enabled only for linear servo motors.
1000
[ȝm]
1 to
65535
PL03
LID
Linear encoder resolution - Denominator
Set a linear encoder resolution per
v
m in [Pr. PL02] and [Pr. PL03].
Set the denominator in [Pr. PL03].
This is enabled only for linear servo motors.
1000
[ȝm]
1 to
65535