FTS 370d/w/r Revision 10 – 1/09/2015 77
Section 5 – Maintenance and Troubleshooting
Safety
Warning!
Read the warning on Page ii now.
Disconnect primary power before opening
enclosures.
Work safely, as follows:
1. Remove rings and watches before
opening the equipment.
2. Shut off power to the equipment and
wait 5 minutes before proceeding.
3. Remove the component or connect the
test instruments.
4. Replace the component.
5. Apply power to the equipment and test
the system.
6. Shut off power to the equipment and
disconnect the test equipment.
Preventive Maintenance
Carry out the following inspection and
cleaning procedures at least once a year:
1. Verify that moisture has not
accidentally entered the equipment
through gaskets or seals, or collected
inside as condensation.
2. Verify that all drain holes are clear.
3. Check terminal blocks and relays for
corrosion or arcing. Clean or replace
any component that shows evidence of
high-voltage damage.
4. Check all electrical connections for
tightness and verify the absence of
corrosion or electrical arcing.
5. Clean the outside surface of the lens
with liquid detergent and water. Wipe
it gently with a soft cloth or paper
towel.
Storage
When not in use, equipment should be
stored indoors. Circuit boards (PCB’s),
when not installed in the equipment,
should be kept in antistatic bags or
containers.
RFI Problems
The presence of radio frequency
interference (RFI) can burn out
components; cause a light to flash
intermittently, at the wrong rate, or at the
wrong intensity. RFI can enter the light by
any wire to or from the unit. The circuits
are designed to reject or bypass RFI, but
Flash Technology cannot guarantee
complete immunity. After installation,
you may find it necessary to add external
filters or use other methods to reduce RFI
entering the equipment.
Diagnostic Test
The SC 370 has built in diagnostic
capabilities to assist in troubleshooting the
system. Flash Technology recommends
that a full system diagnostic test is run
before troubleshooting individual system
components.
Component Testing
Always make resistance measurements
with the primary power turned off.
However, you must make voltage
measurements with power applied. Thus,
for your safety, carry out all preliminary
steps such as connecting test leads or
circuit jumpers or disconnecting existing
circuit connections with the power off.