FTS 370d/w/r Revision 10 – 1/09/2015 103
Marker Settings and Diagnostics
Register
Address Read/Write Register Name Description / Values
240 R/W Marker Tier Select Register
1
-
6, indicates/selects which system Marker Tier data is
reflected below
242 – 272 R
Marker
Board
Firmware
Revision String
ASCII string, null terminated
273 – 288 R
Marker
Board
Universally
Unique Identifier
Binary data identifier
289 R
Marker Output 1 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 1
290 R
Marker Output 2 Current Draw
A2D
An
A2D value representing the current draw of Marker
Output 2
291 R
Marker Output 3 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 3
292 R
Marker Output 4 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 4
293 R Marker Drive Voltage A2D
An A2D value representing the voltage that is driving all
the Marker Outputs
294 R
Marker Input Power Voltage
A2D
An A2D value representing the Input Power Voltage Level
295 R
Marker Internal Temperature
A2D
An
A2D value representing the Marker
Box
Internal
Temperature
296 R Individual Marker Status
If a marker alarm is detected in Tower Monitoring
(register
82), the specific marker that failed can be determined
here:
Bit 0 – A ‘1’ indicates that Marker 1 is in alarm
Bit 1 – A ‘1’ indicates that Marker 2 is in alarm
Bit 2 – A ‘1’ indicates that Marker 3 is in alarm
Bit 3 – A ‘1’ indicates that Marker 4 is in alarm