FTS 370d/w/r Revision 10 – 1/09/2015 55
Section 3 – Information Display
Navigating the Information Display
Three pushbuttons to the right of the
information display provide access to
navigate the system menus, configure the
system and review diagnostic information.
Table 3-1 describes the function of each
button. The top level menu is described in
Table 3-2. Each menu option is discussed
in the headings following Table 3-2.
Figure 3-1 – Information Display
Table 3-1 – Controller Display Buttons
1
Button Function
S1 UP
Navigates UP through the active menu options.
S2 ENTER
Confirms your selection or Advances to the NEXT option. Press and
hold for 1.5 seconds then release to return to the previous menu.
Press and hold for longer than 5 seconds to return to the main menu.
S3 DOWN
Navigates DOWN through the active menu options.
Table 3-2 – Top Level Menu Options
1
CONTROL TYPE Selects the role of the unit as System 1 or subordinate System 2-6
SITE TOWER CONFIG Selects the overall system configuration. (System 1 only)
LOCAL TOWER CONFIG Selects the individual unit configuration.
MONITORING CONFIG
Selects the type of monitoring equipment that will be used to monitor
the system. (System 1 only)
MONITORING STATUS Provides status of the built in monitoring system. (System 1 only)
LOCAL DIAGNOSTICS
Displays the firmware revision and multiple analog values for the
controller, beacon and markers. This menu is especially helpful when
troubleshooting the system.
LIGHTING INSPECTION
(LI)
Allows the user to perform a lighting inspection. Automatic and Manual
modes are available.
MODE OVERRIDE
Allows the system to be manually placed in any capable mode for a
user definable period of up to 24 hours.
FACTORY TEST Factory use only.
SYSTEM REBOOT
Allows the user to reboot the system without physically interrupting
input power.
FACTORY DIAGNOSTICS Factory use only.
SYSTEM X FIRMWARE
2
(System 1 only)
This feature allows System 1 to display, and if appropriate, upgrade the
firmware version of each connected subordinate unit to its current
version.
2
1. Menu options and features are based on firmware version 3.1.
2. Subordinate units must have firmware Version 3.0 or higher installed to receive firmware upgrade from System 1.