FTS 370d/w/r Revision 10 – 1/09/2015 9
P2 Auxiliary Input
The Auxiliary Input (previously labeled
LOW BAT) allows an external device,
such as a radar system, to inhibit the
output of the beacon. Control via the
Auxiliary Input is limited to systems
consisting of a single SC 370 power and
control unit. Control is supplied by a dry
contact in the external device and is
connected to “Aux In” (P2 terminal 3) and
“DC –” (P2 terminal 1). The fail-safe
design requires a closed contact to inhibit
the output of the beacon.
Any unused dry contact may be reassigned
to provide confirmation that the system is
operating normally while the beacon
output is inhibited. See Figure 1-4 and
Table 1-4 for available dry contacts.
Auxiliary Input configuration
programming is located in the “Site Tower
Configuration” menu of the controller
programmed as System 1. See Section 3
for additional information regarding this
feature.
Note: Firmware 2.9 or above is required
for Auxiliary Input Control. The beacon
output may also be controlled by Modbus.
See Section 3 and Appendix A for
additional information.
J4 Communication Cable
Connection
FTS 370 systems
consisting of more than
one SC 370 unit require
connection of a
communication cable
between units. J4,
located on the lower
right of PCB1, provides
connection for two RJ
45 connectors. The double RJ 45
connector allows the communication
cables to be daisy chained from System 1
to each subordinate unit. Either port may
be utilized as an input to or output from
PCB 1. See “Communication Cable Kit”
in Section 2 for additional connection and
cable routing information.