Sharp YO-370 Instrukcja Obsługi Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 12
FTS 370d/w/r Revision 10 – 1/09/2015 1
Section 1 – Introduction and Operation
Introduction
FTS 370d and FTS 370w are LED
Medium Intensity Obstruction Lighting
Systems. FTS 370d series are Dual
Lighting Systems (red/white) for L-
864/865 applications. FTS 370w series
are White Lighting Systems for L-865
applications.
FTS 370 series lighting systems may also
be configured for Catenary operation.
Catenary lighting systems require three
levels (tiers) of lights. One tier is installed
at each of the following three locations:
top of the structure, lowest point of the
catenary and half way between the upper
and lower levels. Each level must be lit to
provide 360-degree coverage. The flash
rate is 60 flashes per minute in all modes
and the flash sequence is as follows:
middle – top – bottom.
FTS 370d Catenary series are Dual
Lighting Systems for L-866/885
applications. FTS 370w Catenary series
are White Lighting Systems for L-866
applications. FTS 370r series are Red
Lighting Systems for L-885 Catenary
applications only.
System Overview
The FTS 370d, FTS 370w and FTS 370r
LED Lighting Systems have been
designed for long life, reducing the need
for service. Ease of installation and
service is enhanced by simple wiring,
setup, and diagnostics. Increased safety is
provided with operating voltages of less
than 60VDC.
Each Lighting System consists of one or
more SC 370d, SC 370w or SC 370r, here
after referred to as SC 370, power and
control unit(s) and its associated
flashhead. Each flashhead requires its
own SC 370. A maximum of six (6) SC
370s and associated flashheads may be
connected to form one lighting system.
Optional GPS synchronization is available
if additional SC 370s are required.
The light source for the flashhead is
comprised of LEDs (Light Emitting
Diodes). The LED control circuitry and
drivers are located in the flashhead.
Power Line Communication is utilized as
the communication link between the SC
370 and the flashhead; simplifying
installation and minimizing the number of
conductors required. Installation of FTS
370d systems (L-864/865) requiring L-810
markers is simplified by requiring only
one cable run for both markers and
flashhead. The flashhead may be located
up to 600’ (cable length) from the
controller.
Any SC 370 in the lighting system may be
configured as the control unit which is
referred to as System 1. This unit provides
overall system control including mode
control, synchronization, and alarm
collection and notification. Robust and
highly reliable communication between
multiple SC 370 units is provided by RS-
485.
SC 370 systems may be ordered
configured for operation by AC or DC
input power. AC systems are not sensitive
to input power phase and have an
operational voltage range of 120-240
VAC, 50/60 Hz with no modification
necessary to the input power module. DC
powered systems are available configured
for 24 or 48 VDC. The DC input voltage
must be specified when ordering.
This manual provides guidance and
recommendations for the installation,
operation, and troubleshooting of the
lighting system. Please read this document
in its entirety before installation.
Przeglądanie stron 12