Quick Start Guide FTS 370d/w/r
Warranty activation is required after installation. Call 1-800-821-5825 24/7/365 to activate product warranty.
ITEMS INCLUDED IN THIS SYSTEM
RECOMMENDED ITEMS FOR INSTALLATION
GENERAL INSTALLATION NOTES
System Controller (SC) 370 Flashhead
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• ATTENTION: System contains circuit boards that are stac sensive. Handling precauons required.
•
•
•
•
•
•
•
•
• AFTER COMPLETING INSTALLATION, CALL 1-800-821-5825 TO ACTIVATE WARRANTY.*
• Before calling, have system serial numbers available for the NOC.
IMPORTANT! AFTER COMPLETING HARDWARE INSTALLATION, THE “BINDING” PROCEDURE MUST BE PERFOMED
FOR EACH SC 370 INSTALLED. SEE “LOCAL TOWER CONFIG” LOCATED IN SECTION 3 OF THE MANUAL (PN F7913702)
FOR DETAILS AND PRODCEDURE.
IMPORTANT! DO NOT INSTALL OR REMOVE WIRES FROM TERMINAL BLOCKS OR PCB’S UNTIL DC VOLTAGE INDICA-
TORS ON THE POWER SUPPLIES HAVE BEEN EXTINGUISHED. THIS APPLIES ESPECIALLY TO CONNECTIONS AT PCB1 P1
AND PCB2 P5. IF IT IS NECESSARY TO REMOVE EITHER CONNECTION OR MAKE OTHER WIRING ADJUSTMENTS,
POWER THE SYSTEM DOWN AND WAIT 5 MINUTES BEFORE PROCEEDING.
•
•
•
Each SC 370 must be bonded to the site lightning ground system using AWG #2 wire (minimum)
and tested to insure the total resistance is less than 25 ohms or less.
•
•
•
•
•
•
Ground the flashhead to tower steel using the provided ground lug and AWG #8 (minimum)
wire.
•
•
•
ATTENTION: THE QUICK START GUIDE IS SUPPLIED AS AN AID TO INSTALLING THE FTS 370D/W/R SYSTEM.
PLEASE REFER TO THE PRODUCT MANUAL (PN 7913702) FOR ADDITIONAL INFORMATION REGARDING
INSTALLATION AND SERVICE OF THIS EQUIPEMT.