b Revision 10 – 1/09/2015 FTS 370d/w/r
Flashhead
The LED beacon is wired correctly.
The wires are positioned so no arcing can occur and wire colors match the terminal designations, and flashhead cable
is secured in the terminal block.
The dome nut of the beacon’s cable strain relief is tightened for cable support and to prevent moisture intrusion.
Drip loop is present for the LED beacon.
The LED beacon is securely closed with both latches in place.
The LED beacon at the top of the tower has a lightning rod(s) provided at least 36” above the top of the beacon, and a
minimum of 18” away from the beacon.
The LED beacon is level (Use separate leveling tool).
8 AWG (min.) insulated ground wire is used from the LED beacon grounding lug to the tower structure.
The LED beacon is mounted in an FAA approved location (No obstructions; allowing a 360° view of the beacon).
Marker Interface Junction Box (SC 370d only)
The Marker Interface Enclosure is mounted at the marker tier level.
Flash Technology provided hardware used for mounting the Marker Interface Enclosure (4 points of contact to Universal
Mounting brackets).
Both latches are secured to prevent water intrusion.
Marker Interface Enclosure is grounded to the tower.
8 AWG (min.) insulated ground wire is used from the Marker Interface Enclosure grounding lug to the tower structure.
Side marker cable connections match all PCB labels (Connections are polarity sensitive, correct wiring is critical).
Service loop for the flashhead cable to the ground is present near the base of the Marker Interface Enclosure.
Service loop for the flashhead cable to the flashhead is present near the base of the Marker Interface Enclosure.
MARKERS (Steady-burning Red LED sidelights, side-markers, or obstruction lights L-810)
Only Flash Technology provided 24 Volt DC Marker Fixtures are installed.
The dome nuts of the cable strain reliefs are tightened for cable support and to prevent moisture intrusion.
Drip loop is present at the marker fixtures.
PHOTODIODE (PHD 512)
The PHD 512 is connected to PCB2 (Surge Board) P-6 (White and Black wires correspond to the label on board).
The PHD 512 is mounted vertically to prevent water entry.
The PHD 512 cable is protected through conduit so it will not be stepped on or damaged.
The PHD 512 is facing north and no artificial lights (security lights, street lights, lighted signs, or direct sunlight) will affect
its operation.
ALARMS and ALARM WIRING
NO alarm LEDs are lit on PCB1 of the SC 370.
The display located on PCB1 of the SC 370 is showing “Status OK” along with the correct configuration of the system type
installed (Dual or White with the correct number of beacons, and markers if applicable).
A Lighting Inspection has been performed via the User Interface Panel.
Call 1-800-821-5825 if additional TECHNICAL or INSTALLATION assistance is needed.