74 Revision 10 – 1/09/2015 FTS 370d/w/r
System “X”
The System “X” Configuration menu is
similar to the Local Tower Config Menu”
with one exception: the Bind and Unbind
features are only available on single
beacon systems (one SC 370 controller).
Only the bind status will be displayed
when more than one SC 370 is installed.
Catenary Level programming will be
displayed if Catenary is selected in Tower
Lighting menu.
Note: The Discovery” and “Unbind
Tower” options are available on single
beacon systems only (one SC 370).
See Section 3 “Local Tower Config” for
information regarding “Discover” and
“Unbind Tower”.
Reportable Events Configuration allows
the end user to determine which events are
reported to the monitoring center via Eagle
or SNMP. By default, all reportable
events are configured as “Enabled”. To
disable specific events, select the
“Disable” button located to the right of the
event. Once all desired events are
selected, press the “Commit Settings”
button near the bottom of the page. State
changes for events that have been disabled
will appear on the web interface with a
gray circle as the indicator. Disabling
reportable events does not impact alarm
dry contacts, Modbus, Event Log, alarm
LED indicators or information displayed
locally by the user interface. Disabling of
alarm events, prior to issuing all required
notifications, is discouraged.
Important! Flash Technology
discourages disabling alarms prior to
issuing all required notifications.