FTS 370d/w/r Revision 10 – 1/09/2015 59
Site Tower
(System 1
only)
Tower Type
Red
White
Dual
Number of Beacons
1 - 6
Marker Mode
2
Steady
Flashing
Red Flash Mode
3
Efficiency
Legacy
Flashes Per Minute Red
4
20 FPM
30 FPM
40 FPM
GPS SYNC
Enable/Disable
GPS Delay
5
Load Default Value
Yes /No
Yes Confirm?
0000 ms Valid Range 0-3000
Catenary
Yes /No
Dry Contacts
Combined
Separate
PD (Photodiode) Alarm
Disarm
6
On /Off
Auxiliary
Input
7
Help
A Secondary System Can Use The Auxiliary Input To Command Lights
On/Off.
Command
Status On /Off
Control Type
Help
Auxiliary Input Can Be Controlled By Either Modbus Or
Dry Contact, But Not Both.
Disabled
Modbus
Dry Contact
Confirm
Output
Configuration
Help
Choose Which Dry Contact Output To Override With
Auxiliary Input Lights On/Off Command Confirmation.
Disabled
Mode Status
Comm Alarm
GPS Sync. Alarm
Photodiode Alarm
Marker Alarm
Night Alarm
Day Alarm
Heartbeat
8
Range Is 0 - 65535
(Value 100 = 10.0s)
IR Enable
3
Help To enable infrared beacon, the beacon must support IR.
Yes/No
IR Is Night Alarm
Help When selected, an IR alarm will also cause a night alarm.
Yes/No
1. Must be set to “1” when using Auxiliary Input.
2. If “Flashing” is selected, the markers will flash in synchronization with the beacon.
3. “Legacy” mode is operational only when 20 FPM is selected. Red Flash Mode selection is overridden in Catenary mode
or when 30/40 FPM is selected. IR beacons ignore “Legacy” mode.
4. Beacon will flash in “Efficiency” or “Legacy” mode when 20 FPM is selected. Beacon will only flash in “Efficiency”
mode when 30 or 40 FPM is selected.
5. GPS SYNC must be Enabled for GPS Delay menu option to be displayed.
6. The 19 hour mode timer is intended to provide notification of a possible failure in the system. The disarm feature
should only be activated if the system is installed in a location prone to periods of light or darkness that would exceed the
19 hour mode timer.
7. Feature available in Firmware V2.9 and above. “Number Of Beacons” must be set to 1.
8. Used only when Auxiliary Input is controlled by Modbus to provide a fail-safe in the event of a communications failure
between the SC 370 and the external control device.
Note: Verify that the lighting system is programmed to operate as described by the FAA
determination for the structure.