FTS 370d/w/r Revision 10 – 1/09/2015 93
Table A-3 – Informational INFORMs
Name
Default
Severity
Description OID
systemCommunicationAlarmNotify Info
System Communication Alarm (SYS COMM):
General communications failure indication.
Any communication failure in the system will
generate a SYS COMM failure on System 1.
The SYS COMM alarm will be accompanied by a
specific communication alarm if the failure is
local to System 1. Absence of a specific
communication failure on System 1 indicates a
communication failure on a subordinate unit
(System 2-6). A communication failure on any
subordinate unit will be accompanied by a SYS
COMM alarm.
.1.3.6.1.4.1.9882.1.2.1.1.6
lightingInspectionTestModeNotify Info
Lighting Inspection Test Mod
e (LI TEST MODE):
Indicates that System 1 is conducting a Lighting
Inspection test on the system.
.1.3.6.1.4.1.9882.1.2.1.1.8
systemVoltageHighNotify Info
System Voltage High INFORM:
The tower voltage is higher than normal.
This only applies to the primary lighting system
(System 1).
.1.3.6.1.4.1.9882.1.2.1.1.9
systemVoltageLowNotify Info
System Voltage Low INFORM:
The tower voltage is lower than normal.
This only applies to the primary lighting system
(System 1).
.1.3.6.1.4.1.9882.1.2.1.1.10
siteModeOverrideNotify Info
Site Mode Override INFORM:
The site tower lighting mode has been
overridden.
.1.3.6.1.4.1.9882.1.2.1.1.12
communicationChangeNotify Info
Communication Change INFORM:
The System 1 controller has lost or regained
communication with a flash head, marker tier,
or another system controller.
.1.3.6.1.4.1.9882.1.2.1.1.13
automaticUpdateNotify Info
Automatic Update INFORM:
A INFORM which is sent based on a configured
time interval.
.1.3.6.1.4.1.9882.1.2.1.1.14
populationChangeNotify Info
Population Change INFORM:
The System 1 Controller has detected a change
in the number of system controllers connected
to it via RS485.
.1.3.6.1.4.1.9882.1.2.1.1.15
lowTowerLightingDCVoltageAlarm
Notify
Info
Low Tower Lighting
DC Voltage Alarm (LOW
DC):
Output voltage (60 VDC) to the connected flash
head and marker tier
(if present) is low.
.1.3.6.1.4.1.9882.1.2.1.1.19
photodiodeModeChangeNotify Info
Photodiode Mode Change INFORM:
The photodiode mode has changed. This is not
an alarm.
0) Day
1) Night
.1.3.6.1.4.1.9882.1.2.1.1.22