Przeglądanie stron 120
MX-M182 DISASSEMBLY AND ASSEMBLY 10-15
11.Developing section
A. Developing box
B. Developing doctor
Adjustment: Developing doctor gap adjustment
C. MG roller
Adjustment: MG roller main pole position adjustment
Note:Attach it to fit with the attachment reference when replacing the DV
blade.
No. Contents
A Developing box
B Developing doctor
C MG roller
(2)
(3)
(3)
(3)
(4)
(1)
(1)
(2)
(5)
(4)
(3)
(3)
0
0.5
0
0.5
Attaching
reference
DV blade
Mark-off line
Mark-off line
reference
The DV blade surface must be free
from foreign materials.
Do not touch the DV blade tip.
It must be free from deflection.