Section-3 Operation
October 17, 2013
340
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
Figure 3-38 LPU RS232, CAN and SNMP Screens 2 & 3
Table328XmtrHome>ExciterHome>Setup>RemoteCommunications>Next&Next
Field Explanation
RS232
BaudRa
te(kHz),databits,parity&stopbitsvaluesaredisplayed.Usethesevalueswhen
connectingviaRS232.
CAN
ExciterID
EnterEx
citerAorB.Note:Whendualex citersareusedtheymustbesettodifferentvalues.If
botharesettoExcit erAcontrolproblemswillresultandthetransmitterwillcycleonandoff.
BaudRat
e(kHz) Baudrateisdisplayed.
SNMPSetup
TrapIPAd
dress AlistoftheIPaddressestowhichanygeneratedSNMPtrapswillbesent.
ReadWr
iteCommunity Thisisapasswordwhichallowsasettobeperformed.Defaultis‘private’.
SNMPVe
rsion
Choicesar
e1or2C.
Version1:Thetr
apwhichissenttellsofanoccurrenceofaneventbutgivesnodetails.
Version2C:Thistr
aptellsofanoccurrenceofaneventandgivesdetailsconcerningit.
Set:Of
f/On
Port Portnu
mber.
Set Choicesar
eOff/On.