Sharp JW-20RS Instrukcja Użytkownika Strona 137

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 230
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 136
9·39
9
Turn to program mode (stop PC operation). Setting of parameters is only available when the PC
is in program mode.
(Operation example of JW-13PG)
•Setting of the parameter is only available when the operation of the JW-20CM is stopped.
•Write “00
(H)
” to parameter address 007777
(8)
and stop operation of the JW-22CM.
(Operation example of JW-13PG)
Stop PC operation
Select initial mode
Select parameter setting mode.
To the next page
Parameter
setting
()
Screen display of JW-13PG
07775 HEX 00
07776 HEX 00
I PARAM.
>07777 HEX 00
• key: Changeover unit of figures
HEX
(hexadecimal)
OCT
(octal)
DCM
(decimal)
Bit pattern
←→
Connect a support tool with the JW-20CM and prepare
the setting parameter.
<Usable support tools>
JW-13PG/12PG
JW-50SP
JW-50PG, Z-100LP2S
For operation of each support tool, see the instruction
manual attached. The following describes an example
of JW-13PG’s key operation.
“Run” the slave station PC
Turn “ON” the power of the master station PC and connect support tools
Stop operation of data link [HEX (hexadecimal), byte]
Stop PC operation
Reference
Function of JW-13PG
• key: Byte display Changeover word display
()
Write
00
(H)
.
Display the contents of parameter
address 007777 by hexadecimal.
Przeglądanie stron 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 229 230

Komentarze do niniejszej Instrukcji

Brak uwag