MAINTENANCE AND SERVICING
Form 169000 / 169040 117 Revision C
7.6.4 Sealed Bearing Installation
a. Clean shaft and coat with rust preventative.
b. Install flangette (A), bearing (B), second
flangette (C), and lock collar (D).
NOTE
The locking cam is only on one side of
the bearing.
c. Install (but do not
tighten) the flangette bolts (E).
d. When the shaft is correctly located, lock the lock
collar with a punch.
NOTE
The collar should be locked in the same
direction the shaft rotates. Tighten the
set screw in the collar.
e. Tighten the flangette bolts (E).
f. Loosen the flangette bolts on the mating bearing
one turn, and re-tighten. This will allow the
bearing to line up.
C
D
E
A
B