SERVICE MANUAL
AE3XM18JR
S1804AEX3M18J
AE-X3M18JR
Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the
safety and performance of the set.
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
CHAPTER 1. SPECIFICATIONS
[1] SPECIFICATION............................................ 1-1
[2] EXTERNAL DIMENSION............................... 1-2
[3] CAPACITY TABLE ......................................... 1-3
[4] ELECTRICAL PARTS .................................... 1-3
[5] WIRING DIAGRAMS...................................... 1-4
CHAPTER 2. EXPLANATION OF CIRCUIT AND OP-
ERATION
[1] BLOCK DIAGARM ......................................... 2-1
[2] FUNCTIONS .................................................. 2-2
[3] ACTIVE FILTER CIRCUIT ............................. 2-4
[4] EXPLANATION OF IPM DRIVE CIRCUIT........ 2-6
CHAPTER 3. FUNCTION AND OPERATION OF PRO-
TECTIVE PROCEDURES
[1] PROTECTIVE FUNCTIONS AND OPERA-
TIONS ............................................................ 3-1
[2] TROUBLESHOOTING GUIDE ......................3-2
CHAPTER 4. REFRIGERATION CYCLE
[1] REFRIGERATION SYCLE.............................4-1
[2] REFRIGERANT PIPE INSTALLATION
WORKS .........................................................4-2
CHAPTER 5. DISASSEMBLING PROCEDURE
[1] OUTDOOR UNIT...........................................5-1
Parts List
TopPage
CONTENTS
MULITI SPLIT TYPE
ROOM AIR CONDITIONERS
(OUTDOOR UNIT)
MODEL
In the interests of user-safety (Required by safety regulations in some countries)
the set should be restored to its original condition and only parts identical to those
specified should be used.
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 - AE-X3M18JR

SERVICE MANUALAE3XM18JRS1804AEX3M18JAE-X3M18JRParts marked with " " are important for maintaining the safety of the set. Be sure to replace

Strona 2 - CHAPTER 1. SPECIFICATIONS

AEX3M18JR2 – 2[2] FUNCTIONS1. FREQUENCY CONTROL1) AC current peak control2) Prevention control of outdoor heat exchanger overheatingIf the temperature

Strona 3 - [2] EXTERNAL DIMENSION

AEX3M18JR2 – 39. PUMP DOWN SWITCHWhen the PUMP DOWN SWITCH (SW1) is pressed for 5 seconds ormore, the total A/C system will start its TEST RUN automat

Strona 4 - [4] ELECTRICAL PARTS

AEX3M18JR2 – 4[3] ACTIVE FILTER CIRCUITThis circuit uses Active Filter Module and IPM as the figure below for the high efficiency operation of compres

Strona 5 - [5] WIRING DIAGRAMS

AEX3M18JR2 – 53. Active Filter Driving Electronics Circuit At the operation of compressor, the microcomputer (IC1), as the 50th pin gets “H”, will tur

Strona 6 - POWER SUPPLY P.W.B

AEX3M18JR2 – 6[4] EXPLANATION OF IPM DRIVE CIRCUITThe power supply for the IPM drive, and the shunt resistor for over current detection, etc., are pro

Strona 7

AEX3M18JR2 – 73. 120° energizing control (digital position detection control)This control system detects the digital position detection signal and adj

Strona 8 - (CONTROL PWB)

3 – 1CHAPTER 3. FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES[1] PROTECTIVE FUNCTIONS AND OPERATIONSNO. Function OperationDescription Detection time

Strona 9 - [1] BLOCK DIAGARM

3 – 2✩1 The outdoor unit restarts four times before the indoor unit error is displayed (complete shutdown).[2] TROUBLESHOOTING GUIDE1. SELF-DIAGNOS IS

Strona 10 - [2] FUNCTIONS

3 – 30-01-05-06-07-08-011-02-0-1-2-3-1-2-3-1-2-5-4-1-2-3Status ofindoor/outdoorunitsIndication byLED1 onoutdoor unit*2Indication on indoor unitContent

Strona 11

3 – 4Status ofindoor/outdoorunitsIndication byLED1onoutdoor unit*2Indication on indoor unitContent of diagnosisInspection location/methodRemedyFloor /

Strona 12 - [3] ACTIVE FILTER CIRCUIT

AEX3M18JR1 – 1AEX3M18JRService Manual CHAPTER 1. SPECIFICATIONS[1] SPECIFICATIONNOTE: The condition of star “✩“marked item are ‘ISO5151’: *: Represent

Strona 13 - AEX3M18JR

3 – 5CHECK METHODCAUTION: CHECKING PRINTED CIRCUIT BOARDS (PWB)Non-insulated control circuitThe GND terminals of the low-voltage circuits (control cir

Strona 14

3 – 6To measure the resistance, first remove the connector from the board. 2. How to distinguish the defective parts1. When all rooms are not cooledTh

Strona 15

3 – 7YesNoYesYesYesYesNoNoNoNoYesNoNoNoNoNoNoNoNoNoYesYesYesYesYesYesYesYesOpen circuit of theoutdoor thermistorReplace thethermistor.Replace the fan

Strona 16

3 – 82. When one room is not cooled (other rooms are cooled)3. When all rooms are not heatedYesYesNoYesNoNoNoYesNoNoYesYesShort circuit of the thermis

Strona 17 - Main category Sub-category

AEX3M18JR4 – 1AEX3M18JRService Manual CHAPTER 4. REFRIGERATION CYCLE[1] REFRIGERATION SYCLERefrigeration CycleFlow of Refrigerant1. Cycle temperature

Strona 18

AEX3M18JR4 – 2Standard conditions2. PERFORMANCE CURVESNOTE: Total cooling capacity and total input with 3 units running.At Cooling for AY-XPM7FR (for

Strona 19 - Outdoor unit

AEX3M18JR4 – 38) Fully open the stop valve (gas side) with hexagon socket screwkey. Turn all the way up to contact.9) Disconnect the gauge manifold ho

Strona 20 - CHECK METHOD

AEX3M18JR5 – 1AEX3M18JRService Manual CHAPTER 5. DISASSEMBLING PROCEDURE[1] OUTDOOR UNITCAUTION: DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY SERV

Strona 21 - Resistance (k )

AEX3M18JR5 – 27. Disconnect the 9 connectors.Expansion valve (CN12A, CN12B, CN12C): 3pcs. Thermistor (CN8A, CN8B, CN8C): 3pcs.Fan motor (CN3): 1pc.Rev

Strona 22

AEX3M18JR5 – 313.Remove the 3 screws fixing the coil for PFC then remove itNOTE: When the coil re-install, silicone grease must be paste to theback fa

Strona 23 - Replace the indoor

AEX3M18JR1 – 2[2] EXTERNAL DIMENSION117320242452284645621210151940323890290505570 17052527417932064552789095060

Strona 24 - REFRIGERATION CYCLE

AEX3M18JR5 – 418.Disconnect the 5 terminals (T1, 2, 4, 6, MRY1) and 3 connectors(CN14, CN2, CN13 (Active Filter)).19.Remove the 3 screws fixing the po

Strona 25

AEX3M18JR5 – 525.Disconnect the 6 terminals (P, Io, +, -, L1, L2) and 1 connector(CN13) on the active filter. And Remove the 2 screws fixing thepower

Strona 26

AEX3M18JR5 – 6MEMO

Strona 27 - DISASSEMBLING PROCEDURE

PARTS LISTMULITI SPLIT TYPEROOM AIR CONDITIONERS(OUTDOOR UNIT)MODELThis document has been published to be usedfor after sales service only.The content

Strona 28

AEX3M18JR2[1] OUTDOOR UNIT4-14-56-56-51-61-651-626-52-72-22-22-32-172-112-166-116-116-122-102-842-262-66-102-192-52-982-82-222-22-92-992-932-122-652-1

Strona 29 - Control board unit

AEX3M18JR3NO. PARTS CODEPRICE RANKNEW MARKPART RANKDESCRIPTION[1] OUTDOOR UNITCABINET AND UNIT PARTS1-1 CCHS-A789JBTB BD Base pan assembly1-2 CMOTLB05

Strona 30

AEX3M18JR4NO. PARTS CODEPRICE RANKNEW MARKPART RANKDESCRIPTION2-12 PSEL-C376JBEZ AC Insulator2-13 PRDAFA215JBEZ BE Haet sink2-14 PRDAFA216JBEZ BC Heat

Strona 31 - Expansion valve

AEX3M18JR5NO. PARTS CODEPRICE RANKNEW MARKPART RANKDESCRIPTION[4] PACKING PARTSNO. PARTS CODEPRICE RANKNEW MARKPART RANKDESCRIPTION[2] CONTROL BOARD U

Strona 32

AEX3M18JR6INDEXPARTS CODE No.PRICE RANKNEW MARKPART RANK[ C ]CCHS-A789JBTB 1-1-1 BDCCIL-A133JBEZ 1-3-1 ASCFTA-A282JBKZ 1-1-71 AWCMOTLB051JBEZ 1-1-2 B

Strona 33 - AE-3XM18JR

AEX3M18JR7RIC--A025BDE0 2-IC3 IC12 AERMOTSA031JBZZ 1-3-20 BCRRLYDA008JBZZ 2-RY1 AHRRLYDA012JBZZ 2-MRY1 ARRR-WZA028JBE0 3-R100 AERTHM-A022JBE0 1-2-80 A

Strona 34 - [1] OUTDOOR UNIT

AEX3M18JR1 – 3[3] CAPACITY TABLECOOLING CAPACITY TABLEHEATING CAPACITY TABLE[4] ELECTRICAL PARTSRecommended CombinationOutdoor Units Indoor UnitsAY-XP

Strona 35

– 1EndPageCOPYRIGHT © 2008 BY SHARP CORPORATIONALL RIGHTS RESERVED.No part of this publication may be reproduced, storedin retrieval systems, or tran

Strona 36

AEX3M18JR1 – 4[5] WIRING DIAGRAMSIPM P.W.B.from ELECTROLYTIC CAPACITOR C10(+)from ELECTROLYTICCAPACITOR C10(-)from COMPRESSOR TERMINALW "ORANGE&q

Strona 37 - [4] PACKING PARTS

AEX3M18JR1 – 5RELAY P.W.B and POWER SUPPLY P.W.B.from 4 WAY VALVEfrom DIODE BRIDGE DB1 "~"from CONTROLP.W.B. "CN9A"from IPM "

Strona 38

AEX3M18JR1 – 6CONTROL P.W.B and DISPLAY P.W.Bfrom THERMISTORfrom HEAT SINK THERMISTORfrom SUCTION THERMISTORfrom IPM PWB "CN101"from RELAYP.

Strona 39

AEX3M18JR1 – 7(POWER SUPPLY PWB)(IPM PWB)(IPM PWB)(DISPLAY PWB)(RELAY PWB)(CONTROL PWB)C11, C13:FC1ORANGEWHITEREDNR2NR3R491001/4W1001/4WR471001/4WR48R

Strona 40

AEX3M18JR2 – 1AEX3M18JRService Manual CHAPTER 2. EXPLANATION OF CIRCUIT AND OPERATION[1] BLOCK DIAGARMCPUPump down switch circuitUnit A thermo. circui