Sharp AE-A189J Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Klimatyzatory typu split Sharp AE-A189J. Sharp AE-A189J Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
OPERATION MANUAL
Thank you for choosing a SHARP air conditioner. Please read this manual
reference.
thoroughly before using your air conditioner and keep it for future
Split Type Inverter Room Air Conditioner
MODELS AY-X24LCJ AE-X24LCJ
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - OPERATION MANUAL

OPERATION MANUALThank you for choosing a SHARP air conditioner. Please read this manualreference.thoroughly before using your air conditioner and keep

Strona 2

buttons on this control are not applicable to this unit. Press this button to select Timer On setting. Pressing the + or - button during the first 5 s

Strona 3 - Specifications

Press On/Off button to start or stop operation.to switch On or Off the display on the main unit. odelsmto switch BLOW the fan will con tinue to bl ow

Strona 4

o set the guide louvre to a desired position, press Swing Up and Down button continuously for more than 2 seconds and hold until desired position

Strona 5

main unit. Operation will be in Auto Run mode and the temperature setting or fan speed cannot be changed.on the To operate: Press the AUTO/STOP butto

Strona 6

Care and Cleaningat the circuit breakerto prevent the risk of electric shock.pour or spray liquids directly onto the indoor or outdoor units for clean

Strona 7

Care and CleaningRemovingRotate the front panel upwards in the direction of the arrow. Pull the air filter downwards and removefrom the unit.water tem

Strona 8

The air conditioner is not user serviceable.if attempt toIf a bad smell has been accumulated from the environment, clean the air filter.If smells pers

Strona 9

willworkingWater is dripping or leaking from the indoor unitWater is dripping or leaking from the outdoor unitHas the circuit breaker device tripped o

Strona 10

air flow is stopped on the outdoor heat exchanger. The unit will automatically defrost and the indoor unit will stop blowing air for 3-12 mins. Durin

Strona 11 - odelsm

The unit mus t only be installed by authorised air conditioner contractors according to mun icipal or governmen t regulations and in compl iance wi t

Strona 13

A dedicated power supply circuit should be used, in accordance with local electrical safety regulations.The product should be installed by a licenced

Strona 14 - Care and Cleaning

GapGapGapGapHeightGapGapGapGapGap180

Strona 15

is at the lef t, the righ t side sh ould be slightly higher to allow drainage.Spirit LevelgapgapproperDrainage hoses passing through indoor areas shou

Strona 16

All interconnecting wiring between indoor and outdoor unit must be performed by a licenced electrical contractor in accordance with AS/NZS3000.unit to

Strona 17

Remove electrical connection access plate (either right hand side or front) from the outdoor unit.Replace access plate (either right hand side or fron

Strona 18 - ,disco nnect from the power

soapy gas detectionare leaking.Outdoorattachsatisfactorily.Installing the Outdoor Unit

Strona 19 - 1.8m above the floor

satisfactoryto the product.product.Are the inlet and outlet air openingsblocked?Is the quantity of gas charge sufficient for the length of pipe run?ma

Strona 20

Specifications -24- Model AY-X24LCJ;AE-X24LCJ Function COOLING HEATING AC Rated Voltage (V) 220-240 V~ Frequency (Hz) 50

Strona 21

-25- Model of Outdoor Unit AE-X24LCJ Compressor Manufacturer/trademark SANYO Compressor Model C-6RZ146H1A Compressor Type Twin Rotary

Strona 22 - Installing the indoor unit

)RU\RXUUHIHUHQFHSOHDVHHQWHUWKHSDUWLFXODUVRI\RXUSXUFKDVHEHORZDQGUHWDLQZLWK\RXUSXUFKDVHGRFXPHQWDWLRQ0RGHO1R6HULDO 1R'DWHRI3

Strona 23

Collection of such waste should be separated for specialtreatment as required by local regulations. and cleaningingingthat should be prevented.thatNOT

Strona 24 - Installing the Outdoor Unit

FOR LOCATION ENQUIRIES WITHINNEW ZEALANDREGARDING YOUR LOCALSHARP CORPORATION OF NEW ZEALAND LIMITEDVISIT OUR WEBSITE ATSHARP CUSTOMER SERVICESTELEPHO

Strona 26

6612990SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148

Strona 28

, please refer the matter to a qualified air conditioner contractor.To change the airflow direction, adjust the vertical and lateral air flow directi

Strona 29 - $LU&RQGLWLRQHUV

Air conditioners absorb heat in the room and transmits it to the outdoor unit, so that indoor ambient temperatures are decreased. Its cooling capacity

Strona 30 - 1300 135 022

Name and function of each part

Strona 31

Note: Be sure that there are no obstructions between receiver and remote control; Don't drop or throw the remote control; Don't sp

Strona 32

Name and function of wireless remote controlbuttons on this control are not applicable to this unit. Preset temperature is increased by pressing this

Komentarze do niniejszej Instrukcji