9.10 Tool Requirements
Cable Connection Tool
On the IQ-200 circuit board, a standard screwdriver is required
for securing cabling connections.
9.11 Controller Specifications
Microprocessor
The IQ-400 Controller is based on a 80C188EB microprocessor,
operating at 16 MHz. The 80C188EB is a 16-bit processor
(internal operation) with an eight-bit data bus. A 20-bit address
bus provides a 1M Byte addressing range. Other features
include three internal 16-bit timers, interrupt controller (8529
equivalent), multiple programmable chip select decoders with
programmable wait states, and two serial communication
channels.
LEDs and Dipswitches
30 discrete LEDs are provided which the microprocessor
software can individually control. Eight general-purpose
switches are provided for use by the microprocessor software,
and are utilized for mode control, configuration setting, ID
selection, etc. In addition, a Power ON LED and four “Reader
Active” LEDs are provided.
Two Seven-Segment LED Display
Error codes are displayed in Hexadecimal format. Refer to the
error code section for listing of codes and their meanings.
Real Time Clock
A real time clock (DS1302) with battery backup is provided for
time of day information.