Sharp DT-200L Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Projektory Sharp DT-200L. Sharp DT-200L Instruction manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - DT-200/200L

DT-200/200L SERIESINSTRUCTION MANUALDIGITAL THEODOLITE

Strona 2

8ContentsFOREWORD ... 1General Handling Precautio

Strona 3 - FOREWORD

9Standard Set CompositionThe numerical value in parentheses shows the quantity. • Make sure that all of the above items are with the instrument when p

Strona 4 - General Handling Precautions

101 NOMENCLATURE AND FUNCTIONS1.1 NomenclatureCircular levelDisplay window *1)Objective lensSighting collimatorOptical plummet telescopeHorizontal t

Strona 5 - Opening the carrying case

11RS-232C Connector (205 only)Operation keysPlate levelBatteryCross-hair adjustment section coverTelescope focusing knobHandleTelescope eyepieceVerti

Strona 6 - WARNING

12Circular levelDisplay window *1)Objective lensSighting collimatorOptical plummet telescopeHorizontal tangent screwHorizontal motion clampLeveling

Strona 7

13Plate level(207L only)Operation keysLaser axis adjusting screw (with cap)Vertical tangent screwVertical motion clampPlate levelBatteryCross-hair a

Strona 8 - Laser Safety

141.2 DisplayDisplay marks1.3 Operating keysDisplay Contents Display ContentsVVertical angleTILTTilt correction mode(DT-205/205L only)HRHorizontal ang

Strona 9

15Adjustment mode and Selecting modeMode KeyAdjustment mode of vertical angle 0 datum Turn the power ON while pressing the [0 SET] key.Selecting mode

Strona 10 - Contents

162 PREPARATION FOR MEASUREMENT2.1 Setting Instrument Up for MeasurementSetting up the TripodFirst, extend the extension legs to suitable lengths and

Strona 11 - Standard Set Composition

17Centering by Using the Plate Level1) Rotate the instrument horizontally by using the Horizontal motion/clamp screw and place the plate level paralle

Strona 13 - DT-209P: Centering

182.2 Power Switch Key ON1Confirm the instrument is leveled.2Turn the power switch ON.Every segment turns on for about 1 second.3Press the [V/%] key.

Strona 14 - DT-205L/207L/209L

192.3 Battery Level IndicatorThe battery power indicator shows the level of battery strength.2.4 Vertical Angle Tilt Correction (DT-205/205L only)When

Strona 15 - DT-205L/207L: Detachable

203 MEASUREMENT3.1 Measuring Horizontal Angle Right and Vertical Angle1Collimate the first target "A".2Press the [0 SET] key twice to set th

Strona 16 - 1.3 Operating keys

213.2 Switching Horizontal Angle Right / Left1Collimate the first target "A".2Press the [R/L] key.The mode Horizontal angle right (HR) switc

Strona 17 - Mode Key

223.3 Measuring from the Required Horizontal Angle1Display the required horizontal angle using the horizontal motion clamp and horizontal tangent scre

Strona 18 - 2 PREPARATION FOR MEASUREMENT

233.5 Repetition Angle Measurement1Press the [FUNC] key.2Press the [REP] key.3Collimate the target "A", and press the [0SET] key twice.4Coll

Strona 19

247Repeat the procedure 5 and 6 to measure the desired number of repetition.8To finish the repetition measurement, press the [FUNC] key and press the

Strona 20 - 2.2 Power Switch Key ON

253.6 Stadia SurveyingThis instrument can be used for stadia surveying, Measurement by stadia is a convenient method for measuring distances with the

Strona 21 - 2.3 Battery Level Indicator

264 HOW TO OPERATE THE LASER(DT-205L/207L/209L only)1Collimate a target.2Press the laser power switch.The laser beam will emit and the green lamp will

Strona 22 - 3 MEASUREMENT

275 THE OTHER FUNCTIONS5.1 Buzzer Sounding for Horizontal Angle 90° IncrementsWhen the horizontal angle falls in the range of less than ± 1° of 0°, 90

Strona 23 - H L 239°29’20”

1FOREWORDThank you for purchasing the TOPCON Digital Theodolite. For the best per-formance of the instruments, please carefully read these instruction

Strona 24

285.5 Detach / Attach of TribrachThe instrument is easily detached or attached to the tribrach, with a tribrach locking lever loosened or tightened fo

Strona 25 - 2AVG

296 SELECTING MODEThe following modes are available6.1 Items of the Selecting ModeSelecting mode 1To set the instrument the selecting mode 1, turn the

Strona 26 - 4AVG

30Selecting mode 2To set the instrument the selecting mode 2, turn the power ON while press-ing the [V/%] key. • Do not change the setting value (0)

Strona 27 - 3.6 Stadia Surveying

316.2 How to Set the Selecting Modes● Selecting Mode 1Sample setting: Auto cut off : OFF, 90° buzzer : OFF1Turn the power ON while pressing the [R/L]

Strona 28 - 4 HOW TO OPERATE THE LASER

326Press the [0 SET] key to set the setting.7Turn the power off. S E T 0 1 0 0 1 0 0

Strona 29 - 5 THE OTHER FUNCTIONS

33● Selecting mode 2Sample setting: [0 SET] key pressing : Once, Tilt correction : OFF1Turn the power ON while pressing the [V/%] key.The instrument

Strona 30 - ● Attachment

347 HANDLING POWER SOURCE7.1 For removing1Push the lock lever downward and pull out the battery.7.2 Replace the battery (DB-35)1Push the hook downward

Strona 31 - (DT-209/209P/

358 CHECK AND ADJUSTMENT● Pointers on the Adjustment1Adjust the eyepiece of the telescope properly prior to any checking operation which involves sigh

Strona 32 - Selecting mode 2

368.1 Checking /Adjusting the Plate LevelAdjustment is required if the axis of the plate level is not perpendicular to the vertical axis.●Checking1Pla

Strona 33 - ° buzzer : OFF

378.2 Checking and Adjusting the Circular Level● Checking1Carefully level the instrument with the plate level only. If the bubble of the circular lev

Strona 34 - Turn the power off

2General Handling PrecautionsBefore starting work or operation, be sure to check that the instrument is functioning correctly with normal performance.

Strona 35

388.3 Adjustment of the Vertical Cross-hairAdjustment is required if the vertical cross-hair is not in a place perpendicu-lar to the horizontal axis o

Strona 36 - 7 HANDLING POWER SOURCE

393Check once more and if the point travels the entire length of the vertical cross-hair, further adjustment is not required.Perform following adjustm

Strona 37 - 8 CHECK AND ADJUSTMENT

408.4 Collimation of the InstrumentCollimation is required to make the line of sight of the telescope perpendicu-lar to the horizontal axis of the ins

Strona 38 - ● Adjustment

41●Adjustment1Unscrew the cross-hair adjustment section cover.2Find Point D at a point between Points C and B, which shouldbe equal to 1/4th the dista

Strona 39 - ● Checking

428.5 Checking and Adjusting the Optical Plummet TelescopeAdjustment is required to make the line of sight of the optical plummet tele-scope coincide

Strona 40

438.6 Adjustment of Vertical Angle 0 DatumIf when measuring the vertical angle of target A at telescope position normal (direct) and reverse settings

Strona 41 - Eyepiece

448.7 Adjustment of Laser BeamThis adjustment must be done after completing following checking and adjusting. 8.3 “Adjustment of the Vertical Cross-ha

Strona 42

459 STORAGE PRECAUTIONS● When returning the instrument to its case, be sure to match the white posi-tioning marks provided with the case and place the

Strona 43

4610 OPTIONAL ACCESSORIESDiagonal Eyepiece, Model 13The diagonal eyepiece is used in place of the telescope eyepiece for making observations up to the

Strona 44

4711 ERROR DISPLAY• If errors still persist after attempting to clear them, contact your dealer or TOPCON.Display Contents CountermeasureAnGLEErrorDis

Strona 45

3Notice on TransceiverWhen using high output transceiver etc., make sure it does not come near the instrument.Opening the carrying caseWhen opening th

Strona 46 - 8.7 Adjustment of Laser Beam

4812 SPECIFICATIONS(DT-205/207/209/209P)Item ItemModelDT-205 DT-207DT-209/209PTelescope Length 149mm 149mm 149mmObjective lens 45mm 45mm 40mmMagnifica

Strona 47 - 9 STORAGE PRECAUTIONS

49*1) Standard deviation based on DIN 18723(DT-205L/207L/209L)Others DimensionDxWxH(mm)149x188x313(5.87x7.1x12.3 in)149x188x313(5.87x7.1x12.3 in)DT-20

Strona 48 - 10 OPTIONAL ACCESSORIES

50*1) Standard deviation based on DIN 18723Laser beamLaser class : Class II (Class 2)Wave length : 633nmMaximum output : 0.6mWLaser beam range : 50mCo

Strona 49 - 11 ERROR DISPLAY

TOPCON CORPORATION75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jpTOPCON POSITIONING SYS

Strona 50 - 12 SPECIFICATIONS

4Display for Safe UseIn order to encourage the safe use of products and prevent any danger to the operator and others or damage to properties, importa

Strona 51 - (DT-205L/207L/209L)

5•Battery can cause explosion or injury.Do not dispose in fire or heat.•Risk of fire or electric shock.Do not use any power voltage except the one giv

Strona 52 - Laser beam

6Laser Safety DT-205L/207L/209L uses the visible laser beam. DT-205L/207L/209L prod-ucts are manufactured and sold in accordance with “Radiation Safet

Strona 53 - TOPCON CORPORATION

7User1) This product is for professional use only!The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to u