4.
Ground Fault Tes
t: With the Selector switch
still in the AC position and the AC Supply cord
disconnected, use an Ohmmeter (set on highest
scale) to measure resistance between the HOT
and GROUND prongs, as illustrated in Figure 7.
Read the Ohmmeter and refer to TABLE 2.
Continuity Test
: With the Selector switch still in
the AC position and the AC cord disconnected,
use an Ohmmeter to measure resistance be-
tween the HOT and NEUTRAL prongs of the AC
cord connector, as in Figure 7. Read the Ohm-
meter and refer to TABLE 2.
5. If the Ground Fault or the Continuity Test meas-
ures a short (0 Ohms), this causes the 3 Amp
fuse to blow. Repeat the test where 0 Ohms was
measured but this time with the AC heater dis-
connected (Reason: to determine whether the
short is in the heater or the controls).
a. If the Ohmmeter still shows a short (0 Ohms),
the control panel has a short. Remove the
Control Assembly and lay back according to
the first four steps of the selector switch re-
moval procedure on page 12-20. Carefully in-
spect all connections for erroneous grounding
of electrical terminals. If nothing found, re-
place the Control Assembly. See page 12-18
for replacement procedure.
b. If the Ohmmeter now shows an open circuit,
the short is in the heater and must be re-
placed.
Figure 7 - Continuity Ground Fault Test - AC
TABLE 2 Ground Fault/Continuity Check
Test Points on AC Cord
Prongs
(See Figure 7)
Ohmmeter Reading Indication Action
Hot Terminal & Prong
0 Ohms
(dead short)
Indicates a
grounding fault
Go to Step 5
Hot Terminal & Prong Open Circuit Normal condition
Possibility of ground
fault is eliminated
Hot & Neutral Terminals 76 - 85 Ohms* Heater is good Go to Step 7
Hot & Neutral Terminals
above 85 Ohms or
below 76 Ohms
Heater is out
of tolerance
Replace heater
Hot & Neutral Terminals
0 Ohms
(dead short)
Indicates a short
in the AC circuit
Go to Step 5
Hot & Neutral Terminals
Open Circuit
(no reading)
Indicates an open
in the AC circuit
Go to Step 6
* If the heater is hot when the measurement is taken, the correct resistance range is 82-91 Ohms.