8) Set the developer cartridges in the sequence of black, cyan,
magenta, and yellow.
9) Put the developer cartridge on the developer unit pawl A, and
press is until pawl P clicks.
(Note) Check that the developer color and the developer unit color
are the same.
10) Pull out the developer cartridge film sheet (1). (4 positions for
each color)
(After completion of the above procedures, attach the removed cover
and the cabinet.)
(2) Toner concentration reference control level setup
1) Enter SIM 25-2 mode with the front cabinet open.
2) Close the front cabinet.
3) Select the developing unit to be adjusted. (Select the all.)
4) Press the EXECUTE key and it is highlighted. The OPC drum
motor rotates and the toner concentration sensor detects toner
concentration and the output value is displayed.
After 3 minutes of stirring, the average value of the toner con-
centration sensor detection level is set (stored) as the reference
toner concentration control value.
(Note) If the adjustment is stopped within 3 minutes, the setup result
is not stored.
When the EXECUTE key is pressed during operation, it is
stopped and the EXECUTE key returns to the normal display.
If "EE-EU" or "EE-EL" is displayed, the reference toner con-
centration control value is not set normally.
EE-EL: The value is less than 79 (1.59V).
EE-EU: The value is over 177 (3.41V).
5) Clear the developer counter with SIM 24-5.
6) Execute SIM 44-27 to reset the half tone correction data (correc-
tion conditions) to the default level.
(Note) 1) The developers of yellow, magenta, and cyan must be
replaced at a time.
If individual developer is replaced, color balance is changed
and cannot be adjusted.
The black developer can be replaced individually.
2) After replacement of the developers and the photoconduc-
tor, execute SIM 44-27 to reset the half tone correction data
(correction conditions) to the default level.
If the above procedure is missed, half tone correction may
not be performed properly.
3) Reset the developer counter with SIM 24-5.
C. Toner setup
1) Open the front cover.
2) Remove the toner box.
3) Press the lock release buttons on the both sides to release lock
and pull the toner box out.
4) The toner supply ports on the toner box are arranged as shown
below.
Lock release buttons
KCMY
AR-C150
4 – 10
Przeglądanie stron 8