Main code Sub code Content
25 01 Drive system check
Used to turn on the main motor, the developing bias, and the discharge lamp for 3 min.
The input value of the toner density is displayed on the second digit of the copy quantity display during the main
motor is rotating.
Copy quantity display
Color of developer
Third digit Second, first digit
A1 ∼ 99 Black
02 Automatic developer adjustment
Same as SIM 25-1. The average value of toner density sensor inputs is stored as the toner density adjustment
value after 3 min from starting the main motor rotation.
The display on the copy quantity display is same as SIM 25-1.
26 05 Count mode setting
Used to set the count mode of the total counter, the developer counter (mini maintenance counter for Japan), and
the maintenance counter in A3/WLT copy.
When this simulation is executed, the currently set count mode is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Total/Developer counter Maintenance count
0 Double count Double count ← Initial value
1 Single count Double count
2 Double count Single count
3 Single count Single count
06 Destination setting
Used to set the destination (Japan, SEC, etc.).
When this simulation is executed, the currently set destination is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Destination
0 Japan
1 SEC
2 SECL
3 SEEG
4 SUK
5 SCA
6 EX inch series
7 EX AB series
8 EX inch series (FC)
9 EX AB series (FC)
10 Taiwan/China
07 Drum sensitivity setting
Used to set the drum sensitivity.
When this simulation is executed, the currently set drum sensitivity is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Drum sensitivity
11
22← Initial value
33
8 – 7